Number Convert
Back to Blog

Tesla vs Gauss: Understanding Magnetic Field Measurements

β€’NumberConvert Teamβ€’8 min read

Learn the difference between tesla and gauss, the two main units for measuring magnetic field strength. Discover how to convert between them and explore real-world applications from MRI machines to Earth's magnetic field.

Listen to this article

Browser text-to-speech

When engineers design MRI machines, physicists study electromagnetic phenomena, or hobbyists explore magnets, they inevitably encounter two units of magnetic field measurement: the tesla and the gauss. Understanding the relationship between these units is essential for anyone working with magnetic fields, from medical imaging specialists to materials scientists.

The Two Systems of Magnetic Measurement

Magnetic field strength, also called magnetic flux density, describes the intensity of a magnetic field at a given point in space. Two measurement systems have emerged to quantify this fundamental physical property: the International System of Units (SI) and the older Centimeter-Gram-Second (CGS) system.

The tesla (T) is the SI unit of magnetic flux density, named after the brilliant inventor and electrical engineer Nikola Tesla (1856-1943). Tesla's groundbreaking work on alternating current and rotating magnetic fields revolutionized electrical power generation and transmission. The unit bearing his name was adopted in 1960 as part of the international standardization of scientific units.

The gauss (G) is the CGS unit, named after the German mathematician and physicist Carl Friedrich Gauss (1777-1855). Gauss made fundamental contributions to mathematics and physics, including pioneering work on magnetism. He developed methods for measuring the Earth's magnetic field and created the first magnetometer.

The Conversion Factor: 1 Tesla = 10,000 Gauss

The relationship between tesla and gauss is straightforward but important to remember:

1 tesla (T) = 10,000 gauss (G)

Or equivalently:

  • 1 gauss (G) = 0.0001 tesla (T) = 100 microtesla (uT)
  • 1 millitesla (mT) = 10 gauss (G)

This 10,000:1 ratio arises from the fundamental differences in how the CGS and SI systems define their base units of length, mass, and time. While the math behind this conversion involves the permeability of free space and unit definitions, the practical takeaway is simple: move the decimal point four places.

Conversion Formulas

Tesla to Gauss:

Gauss = Tesla x 10,000

Gauss to Tesla:

Tesla = Gauss / 10,000

Worked Examples

Example 1: A neodymium magnet produces a surface field of 1.2 T. What is this in gauss?

  • 1.2 T x 10,000 = 12,000 G

Example 2: Earth's magnetic field at the equator is approximately 0.31 G. Convert to tesla:

  • 0.31 G / 10,000 = 0.000031 T = 31 uT (microtesla)

Example 3: An MRI machine operates at 3 T. Express in gauss:

  • 3 T x 10,000 = 30,000 G

Magnetic Field Strengths in the Real World

Understanding common magnetic field strengths helps put these units in perspective. Here's a reference table spanning many orders of magnitude:

SourceField Strength (T)Field Strength (G)
Interstellar space~0.0000000001 T~0.000001 G
Earth's magnetic field0.00003-0.00006 T0.3-0.6 G
Refrigerator magnet0.005 T50 G
Small bar magnet0.01 T100 G
Neodymium magnet (surface)1-1.5 T10,000-15,000 G
Standard MRI machine1.5-3 T15,000-30,000 G
High-field research MRI7 T70,000 G
Laboratory electromagnet2-3 T20,000-30,000 G
Superconducting magnet20+ T200,000+ G
Strongest continuous field (lab)45 T450,000 G
Neutron star surface100,000,000 T1,000,000,000,000 G

MRI Technology: Where Tesla Measurements Matter Most

Medical magnetic resonance imaging (MRI) machines represent one of the most important applications of strong magnetic fields. Understanding field strength in tesla is crucial for medical professionals, researchers, and patients alike.

Standard Clinical MRI: 1.5 Tesla

The 1.5 T MRI scanner is the workhorse of clinical imaging worldwide. At this field strength:

  • Produces 15,000 gauss of magnetic field
  • Sufficient for most diagnostic imaging needs
  • Offers a good balance of image quality and patient comfort
  • Widely available and well-understood technology

High-Field Clinical MRI: 3 Tesla

Many modern hospitals have upgraded to 3 T systems:

  • Generates 30,000 gauss of field strength
  • Provides roughly twice the signal-to-noise ratio of 1.5 T
  • Enables faster scans or higher resolution images
  • Particularly valuable for neurological and musculoskeletal imaging

Research and Specialized MRI: 7 Tesla and Beyond

Research institutions and specialized centers employ ultra-high-field MRI:

  • 7 T systems produce 70,000 gauss
  • Enables visualization of structures too small for lower-field scanners
  • Critical for advanced brain research and cancer detection
  • Some experimental systems reach 10.5 T (105,000 G) or higher

Safety Considerations

The strength of MRI magnetic fields makes safety paramount. Even a 1.5 T field exerts significant force on ferromagnetic objects. Metal objects can become dangerous projectiles, and certain medical implants are contraindicated. This is why the 5-gauss line (0.5 mT) is used as a safety boundary around MRI installations.

Industrial and Scientific Applications

Beyond medical imaging, magnetic field measurements in tesla and gauss are critical across many industries.

Materials Science and Manufacturing

Permanent magnets used in motors, generators, and sensors are characterized by their residual magnetic flux density. Modern neodymium-iron-boron (NdFeB) magnets can achieve surface fields of 1.2-1.5 T. Manufacturing quality control requires precise measurement of these fields to ensure consistent performance.

Particle Physics

Particle accelerators require immense magnetic fields to bend charged particles into circular paths. The Large Hadron Collider at CERN uses superconducting magnets producing over 8 T (80,000 G) to guide protons around its 27-kilometer ring. Precise magnetic field measurement and control are essential for these experiments.

Geophysics and Navigation

Earth's magnetic field, measured in microtesla or milligauss, is crucial for navigation and geological surveys. Magnetometers detecting variations in this field can locate underground mineral deposits, map geological structures, and study Earth's magnetic field dynamics. Typical readings range from 25-65 uT (0.25-0.65 G) depending on location.

Magnetic Storage and Electronics

Hard disk drives rely on precisely controlled magnetic fields to read and write data. While these fields are measured in different units at the recording layer, understanding tesla and gauss helps engineers design better magnetic storage systems. Similarly, magnetic sensors in smartphones and other devices measure fields in the microtesla range.

Why Both Units Persist

Given that the SI system with tesla is the international standard, one might wonder why gauss remains in use. Several factors contribute to its persistence:

  1. Historical momentum: Much of the scientific literature on magnetism was published using CGS units. Gauss values appear in countless reference works and established databases.

  2. Convenient scale: For many everyday magnetic fields, gauss produces more manageable numbers. A refrigerator magnet at 50 G is easier to discuss than 0.005 T.

  3. Field-specific conventions: Some scientific communities, particularly in astronomy and some areas of physics, continue to use CGS units by convention.

  4. Instrumentation: Many magnetometers, especially older or less expensive models, display readings in gauss.

However, the trend strongly favors SI units. Modern scientific publications, engineering specifications, and international standards use tesla. Students and professionals should be comfortable converting between the two systems.

Practical Tips for Working with Magnetic Units

When dealing with magnetic field measurements:

  1. Always clarify units: Before comparing values or making calculations, confirm whether data is in tesla or gauss. A single misplaced decimal point can mean the difference between a mild magnetic field and one that could cause serious harm.

  2. Use appropriate prefixes: For weak fields, microtesla (uT) or milligauss (mG) are more practical. For strong fields, stick with tesla. This keeps numbers in a readable range.

  3. Remember the rule of four: Moving between tesla and gauss means shifting the decimal point four places. Tesla to gauss: move right. Gauss to tesla: move left.

  4. Consider your audience: When communicating about magnetic fields, use units your audience expects. Medical professionals think in tesla; some older technicians prefer gauss.

Conclusion

Tesla and gauss represent two ways of expressing the same physical quantity: magnetic flux density. While the SI unit tesla has become the international standard, gauss remains common in many contexts. The conversion factor of 10,000 between them is straightforward to apply.

From the faint whisper of Earth's magnetic field at 0.5 gauss to the powerful 7 T fields in research MRI machines, magnetic field measurements span an enormous range. Understanding both units and their relationship enables scientists, engineers, and medical professionals to work effectively across disciplines and communicate clearly about this fundamental physical property.

Whether you're designing the next generation of MRI machines, studying magnetic materials, or simply curious about the physics of magnets, mastery of tesla and gauss conversions is an essential skill in understanding our magnetic world.

See what our calculators can do for you

Ready to take control of your finances?

Explore our free financial calculators and tools to start making informed decisions today.

Explore Our Tools
Tesla vs Gauss: Understanding Magnetic Field... | FinToolset